Introscope Shutdown Agents

Sometimes you are "cooking" too much data and there is hardware limitations which freezes the performance at your introscope analysis system.
In this or other cases, you need to shut down an agent, there is the way to:
This kind of operations are managed through Investigator console, first you have to match in wich agent you are connected:

*SuperDomain*|Custom Metric Host (Virtual)|Custom Metric Process (Virtual)|Custom Metric Agent (Virtual) (collecter3@5002)|Agents|hostname45

right click and "shut off hostname45"

this is simply and doesn't need seting up nothing "at the server side".

Other way to isolate the impact, is shutting down individual proccesses data gathering:
source